MyLight ELITE 2.0 Spectrometer Verification & Irradiance Testing
The MyLight ELITE 2.0 by Mychondria combines four MyLight MAX 2.0 panels on a mobile stand. Each panel is the same individually spectrometer-tested unit sold as the standalone MyLight MAX 2.0, measured using a HOPOO HPCS-330Pro spectrometer.
The MyLight ELITE 2.0 uses 630 nm and 660 nm red light together with 850 nm near-infrared light. Per-panel spectrometer testing measured spectral irradiance of 71.937 mW/cm² at 6 inches, 69.320 mW/cm² at 8 inches and 63.340 mW/cm² at 12 inches, the same figures verified for the standalone MyLight MAX 2.0.
Because the MyLight ELITE 2.0 is built from four of the same panels sold individually as the MyLight MAX 2.0, Mychondria publishes the same verification report and original spectrometer measurement data used for the standalone panel, so these per-panel specifications can be independently reviewed.
Device: MyLight ELITE 2.0
Brand: Mychondria
Configuration: Four MyLight MAX 2.0 panels on a mobile stand
Wavelengths: 630 nm, 660 nm and 850 nm
Instrument: HOPOO HPCS-330Pro
Instrument serial number: 334954588
Spectral measurement range: 380–1000 nm
Testing date: September 13, 2026
Device output: 100% with all wavelengths enabled
Sensor position: Center of panel
Warm-up period: 10 minutes for both device and spectrometer
View all Mychondria spectrometer-verified red light therapy testing
View the MyLight ELITE 2.0 product page
View the standalone MyLight MAX 2.0 spectrometer verification page
Why solar meter readings don't tell the full story
MyLight ELITE 2.0 spectrometer test results
Each MyLight MAX 2.0 panel used in the MyLight ELITE 2.0 was tested at 6 inches, 8 inches and 12 inches from the spectrometer sensor, using the same testing process as the standalone MyLight MAX 2.0.
During testing, each panel was operating at 100% output with the 630 nm, 660 nm and 850 nm wavelengths enabled.
| Measurement distance | Spectral irradiance (per panel) |
|---|---|
| 6 inches (15.2 cm) | 71.937 mW/cm² |
| 8 inches (20.3 cm) | 69.320 mW/cm² |
| 12 inches (30.5 cm) | 63.340 mW/cm² |
These are the same per-panel spectrometer-measured spectral irradiance values published for the standalone MyLight MAX 2.0. The MyLight ELITE 2.0's four-panel stand increases total treatment coverage rather than per-panel intensity.
View the MyLight MAX 2.0 Spectrometer Irradiance Verification Report (per-panel data)
Verified 630 nm, 660 nm and 850 nm wavelength output
- 630 nm red light
- 660 nm red light
- 850 nm near-infrared light
The HOPOO HPCS-330Pro measures light across a spectral range of 380–1000 nm, which includes all three wavelengths used by each MyLight MAX 2.0 panel in the MyLight ELITE 2.0.
MyLight ELITE 2.0 flicker testing
| Frequency | 0 Hz |
| Flicker percentage | 0% |
| Flicker index | 0 |
| Duty cycle | 0% |
| Flicker cycle | 0 ms |
No measurable flicker was detected on the MyLight MAX 2.0 panels used in the MyLight ELITE 2.0.
Why four panels instead of one
The MyLight ELITE 2.0 combines four MyLight MAX 2.0 panels on a mobile stand to cover the largest treatment area in the MyLight lineup in a single session, not to increase the irradiance produced by any individual panel. Each panel's measured spectral output and irradiance are identical to the panel sold individually as the MyLight MAX 2.0.
How each MyLight ELITE 2.0 panel was tested
- Each MyLight MAX 2.0 panel and the HOPOO HPCS-330Pro spectrometer were allowed to warm up for 10 minutes.
- The panel was set to 100% output with the 630 nm, 660 nm and 850 nm wavelengths enabled.
- The spectrometer sensor was positioned in the center of the panel.
- Measurements were recorded at 6 inches, 8 inches and 12 inches.
- Spectral irradiance and spectral output were recorded using the HOPOO HPCS-330Pro.
- Flicker was measured using the spectrometer's integrated flicker measurement function.
Spectrometer testing equipment
- Manufacturer: Hangzhou Hopoo Light & Color Technology Co., Ltd.
- Model: HPCS-330Pro
- Serial number: 334954588
- Spectral measurement range: 380–1000 nm
- Software version: 2.0.4
Using irradiance to calculate red light therapy dose
Red light therapy dose is commonly expressed in joules per square centimeter (J/cm²).
Dose (J/cm²) = Irradiance (W/cm²) × Treatment Time (seconds)
Because each MyLight MAX 2.0 panel in the MyLight ELITE 2.0 measures the same as the standalone panel, dose calculations should use the per-panel irradiance value for whichever panel is facing the treatment area.
Frequently asked questions
Is Mychondria a spectrometer-verified red light therapy brand?
Yes. Mychondria uses a HOPOO HPCS-330Pro spectrometer to measure and verify the spectral output and irradiance of its red light therapy devices.
Is the MyLight ELITE 2.0 spectrometer verified?
Yes. The MyLight ELITE 2.0 is built from four MyLight MAX 2.0 panels, each individually tested using a HOPOO HPCS-330Pro spectrometer. Per-panel spectral irradiance, wavelength output and flicker measurements are published on this page.
What is the irradiance of the MyLight ELITE 2.0?
Each MyLight MAX 2.0 panel used in the MyLight ELITE 2.0 measured 71.937 mW/cm² at 6 inches, 69.320 mW/cm² at 8 inches and 63.340 mW/cm² at 12 inches.
What wavelengths does the MyLight ELITE 2.0 use?
The MyLight ELITE 2.0 uses 630 nm and 660 nm red light together with 850 nm near-infrared light.
What spectrometer was used to test the MyLight ELITE 2.0?
Testing was performed using a HOPOO HPCS-330Pro spectrometer, serial number 334954588, with a spectral measurement range of 380–1000 nm.
Does the MyLight ELITE 2.0 have measurable flicker?
The published spectrometer measurements recorded 0% flicker and a flicker frequency of 0 Hz on each panel tested.
Why does the MyLight ELITE 2.0 use MyLight MAX 2.0 spectrometer data?
The MyLight ELITE 2.0 is built from four of the same panels sold individually as the MyLight MAX 2.0, so its per-panel spectral irradiance and wavelength figures are the same as the standalone MyLight MAX 2.0 verification data.
Can I inspect the original spectrometer data behind the MyLight ELITE 2.0 figures?
Yes. The MyLight MAX 2.0 verification report links to the original HOPOO HPCS-330Pro reports from each tested distance, and applies to each panel used in the MyLight ELITE 2.0.
Transparent spectrometer testing
Mychondria publishes the exact per-panel irradiance measurements, wavelengths, testing equipment, testing conditions and underlying spectrometer data for the MyLight ELITE 2.0.